Cargando...
Cargando...

Liners
Drinking water liners for pressure pipes are flexible linings, made of a high-strength textile with an inner polymer layer, that are installed inside an existing pipe to restore its watertightness and its ability to carry service pressure. They are introduced from limited access pits, without opening a trench along the run, and are connected to the network with end fittings designed for the purpose.
There are two main families. In the first, the liner is pulled into the pipe without curing and sits tightly as an independent lining, which allows long runs and moderate changes of direction. In the second, the liner is inverted under pressure and bonded to the pipe wall with a resin, so it works together with the existing pipe. In both cases, the layer in contact with the water is permanent and must hold the applicable sanitary certification.
The choice depends on the working pressure, the condition of the pipe, the diameter, the bends, the branches, and the criticality of the line. The process includes cleaning, inspection, temporary supply to customers and, at the end, flushing, disinfection, and testing before the run returns to service, so that water quality is accounted for at every step.
1 products available
Drinking water lines perform a function that leaves no room for improvisation: delivering safe water, at the required pressure, every day. After decades of service, many show internal corrosion, scale, leaking joints, or repeated bursts, and replacing them by excavation means closing roads, crossing other utilities, and bearing a high social cost. Drinking water liners for pressure pipes offer an alternative for renewing the run without opening the street along its full length.
A liner of this type is a flexible lining made of a high-strength textile, which carries the internal pressure, and an inner polymer layer, which stays in contact with the water. It is installed from limited access pits, and depending on the system it can be pulled into the pipe without curing or inverted under pressure and bonded to the wall with a resin. That is why the design class is an engineering decision. There are independent linings, able to carry the pressure even if the original pipe fails, others with their own ring stiffness that work together with it, and bonded ones that resist the internal pressure while the existing pipe continues to carry external loads. The choice is made based on inspection, the level of deterioration, the working pressure, and the criticality of the line.
Water quality is the starting condition. Materials in contact with drinking water, fittings included, must hold the applicable sanitary certification, and the procedure maintains hygiene throughout the work. It includes cleaning the line beforehand, temporary supply to customers, control of curing when the system requires it and, at the end, flushing, disinfection, and water quality control before the run returns to service.
Ends, fittings, and branches define a large part of the job. The ends of the liner are sealed and connected to the network through end fittings, either through the existing pipe, with a new piece, or directly onto the liner itself, depending on the class. Branches and service connections are reinstated from the inside or through spot excavations, far smaller than a continuous trench, and each case is solved with fittings designed for that type of liner.
Operating benefits include less excavation and traffic disruption, a reduction in leakage losses in the rehabilitated run and a smooth interior surface that helps preserve hydraulic capacity. The effect on losses should be measured: pressure and flow recorded before and after the intervention make it possible to estimate the improvement with data.
It does not apply in every case. It requires a clean line, with sealing surfaces free of irregularities, bends within what each system allows, and a prior internal inspection that confirms its condition. Once the liner is installed, later work on the line, such as cutting or welding, must be planned with the system manufacturer. Typical applications are transmission and distribution lines in dense urban areas, road crossings, railways and watercourses, and runs with recurring bursts.
The recommended path is to start with the inspection and condition assessment of critical runs, prioritize them, and define, for each one, the liner family, the design class, the certified materials, and the sanitary procedure, acceptance tests included. If you are evaluating renewing drinking water lines without excavation, Marfel's team can help you define the project scope and the right solution for each run.